After fitting a cell model, test its predictions against records that you set aside beforehand. Read the voltage errors, the proportion of valid data and the test conditions together. This gives you a clear basis for deciding where to use the model and what to review before the next experiment.

I developed VoltSift to bring CSV checks, model fitting, independent validation and report downloads into one workflow. This guide explains how to read a validation result and how to run an analysis with your own records.

1. Set aside validation records before fitting

Use fitting records to estimate parameters. Use separate validation records to check those parameters against another test. Two distinct tests from the same cell can serve these roles. Keep the acquisition time, load profile and initial conditions for each record. If the validation task involves another cell, retain its sample information and test conditions too.

Choose the split before estimating parameters. Adjacent samples often share the same recent test history. Randomly distributing rows between files can therefore place information from one trajectory in both groups. Splitting by complete test records, or by independent segments that you define in advance, makes the result easier to interpret. If you repeatedly adjust parameters in response to validation errors, reserve another independent record for the final assessment.

VoltSift checks for duplicate files and trajectories. For preparation steps, see the CSV guide for battery modeling and the official CSV documentation.

2. Read errors together with coverage

Start by checking which rows were scored. VoltSift reports the total number of rows, the rows within the declared SOC range and the valid rows that actually contributed to the error calculation. In-domain coverage is the number of scored rows divided by the number of in-domain rows, multiplied by 100%. Rows outside the domain and unscored rows inside it are reported separately.

Metrics to read together in a validation report
Metric What to check
Total rows All rows in the validation record.
In-domain rows Rows within the SOC range that the model declares.
Scored rows Valid in-domain rows used to calculate errors.
In-domain coverage Scored rows as a proportion of in-domain rows.
RMSE Root mean square voltage error over scored rows, in mV.
Maximum error Largest absolute voltage error over scored rows, in mV.

This measured example shows the arithmetic. The WLTP validation record for CALB L148N58A cell #60129 at 25 °C contains 221,437 rows. Of these, 196,347 are in domain (SOC ≥ 20%) and 196,221 are scored. In-domain coverage is 196,221 ÷ 196,347 × 100% = 99.94%. The report also retains 25,090 rows outside the domain and 126 unscored rows inside it, so 25,216 rows are excluded from scoring. Over the 196,221 scored points, voltage RMSE is 3.217 mV and maximum error is 13.051 mV. The data come from the public CALB dataset by Fasolato et al. on Mendeley Data (CC BY 4.0).

These counts connect the reported error to the part of the record that was evaluated. When comparing analyses, check the records, SOC ranges and scoring rules together. VoltSift’s current standard acceptance conditions include RMSE ≤ 10 mV, maximum error ≤ 30 mV and in-domain coverage ≥ 99%. These are decision thresholds. The software calculates the actual errors from each uploaded dataset. See the metric definitions and acceptance conditions.

3. Review driving segments and initial conditions

Whole-record metrics describe the overall error. Review the driving-segment metrics too, then locate discrepancies against current changes, rest periods and SOC intervals. The record result also incorporates model checks. Retain counts for checks that failed, checks that were not run and rows that were excluded.

Check how many scored rows belong to driving segments, then examine the segment errors separately to assess predictions under the target load. For multiple validation records, retain each record’s errors, coverage and pass status, together with the total number of records.

Initial SOC, current direction, time alignment and the OCV reference affect the comparison between predictions and measurements. Check each against the original records and input conventions. Locate the conditions under which a discrepancy occurs before deciding whether to change the data or the model. When its cause remains unresolved, record the observed error pattern.

Save the cell identifier, test date, basis for capacity and load description alongside the report. Use the same record format after changing data or parameters so that you can compare results and their corresponding conditions.

4. Run the workflow in VoltSift

I recommend VoltSift when you have test records and want results that you can review in one place. The current standard workflow supports NMC single cells at 25°C over SOC 20%–100%. Each report retains the conditions for its model. Prepare one fitting CSV, one independent validation CSV and one OCV curve, then submit them using the templates.

After the analysis, review coverage, errors and review notes on the project page, then download the report. Pro and Advanced also provide validation JSON, a ZIP with model parameters, C and MATLAB parameter tables, CSV parameter tables and files for local C99 voltage simulation. Choose a plan using the deliverables listed on the pricing page.

A model delivered after the relevant checks remains a candidate for engineering use. Review its initial state and operating conditions. For a new load profile, assess prediction errors against corresponding measurements. On a target device, check floating-point results and execution time. The integration documentation describes these steps.

5. Start with your first dataset

Try the full workflow with records whose source and conditions you can verify. Assess whether the report gives you what you need for review and further use. No payment card is required to register. After verifying your email, you can run one free analysis within 7 days. For an overview, read the VoltSift guide to cell modeling.